KRMV0402SD240C2R5Y
Technology Data
Symbol
Value
Unit
Maximum allowable continuous AC voltage at 50-60 Hz
VRMS
17.1
V
Maximum allowable continuous DC voltage
Vd
24
Breakdown voltage measured
VB
100±20%
Maximum clamping voltage
VC
198
Maximum peak current
Ip
10
A
Maximum Surge Energy
ET
0.05
J
Capacitance value
Cp
2~6
pF
Reference Data
Response time
Trise
<1
ns
Non-linear coefficient
(α=(log(V1mA/V0.1mA)/ log(IV1mA/IV0.1mA)))
α
>15
/
Leakage current at Vd%
IL
<0.1
μA
ESD Capability (IEC61000-4-2 Direct Discharge)
Level 4
Operation ambient temperature
-40~+85
℃